honeywell thm5320r no signal



honeywell thm5320r no signal

What does "no signal" mean on RF2 programmers

If the message no signal is displayed on the programmer of an RF2 pack it will be accompanied by either a flashing tap symbol or a flashing radiator symbol. There are 2 possible causes why the programmer shows a flashing radiator symbol and "No Signal" is displayed: The DT92E batteries are running low, therefore they need to be changed.

FocusPRO Wireless Thermostats Honeywell

Low signal strength. Move wireless device to a different location and try again. 0 Zone number 0 No zoning (single thermostat used with THM5320R EIM) [Options: select zone 1, 2, 3 or 4] 1 System type 0 1 heat/1 cool conventional 1 1 heat/1 cool heat pump (no aux. heat) 2 Heat only (includes Series 20) Honeywell International Inc. 4

System Installation Guide SupplyHouse

a signal from the wireless network. 3 When the screen displays “Connected,” press DONE. 4 Press NO at the next screen to save and exit. (Or press YES and repeat steps 14 to link another EIM.) WIRELESS SETUP CONNECT Link outdoor sensor to wireless network (optional) 1 Make sure the Connected light on the EIM is flashing (see page 5).

System Installation Guide Honeywell

YES NO CONNECT MORE M 1 Make sure the Connected light on the EIM is flashing (see page 5). 2 Press CONNECT at the remote. There will be a short delay as the remote seeks a signal from the wireless network. 3 When the screen displays "Connected," press DONE. 4 Press NO at the next screen to save and exit. (Or press YES and repeat steps 14

System Installation Guide Honeywell

No zoning (single thermostat used with THM5320R EIM) [Options: select zone 1, 2, 3 or 4] 0 1 heat/1 cool conventional 1 1 heat/1 cool heat pump (no aux. heat) 2 Heat only (includes Series 20) 3 Heat only with fan 4 Cool only 5 2 heat/1 cool heat pump 6 2 heat/2 cool conventional 7 2 heat/1 cool conventional 8 1 heat/2 cool conventional

Honeywell FocusPro TH6320R Thermostat Manual

“No Signal” Thermostat has lost radio contact with the wireless network (usually because of a power outage). To restore power: Check circuit breaker and reset if necessary. Make sure power switch at heating & cooling system is on. Make sure furnace door is closed securely.

Honeywell thermostat troubleshooting: Honeywell

E01 During WiFi Setup, the router lost power. Ensure your router has power. If trying to connect to a hidden or manually added network, confirm the router has power and is working. E02 Invalid WiFi password. This code displays for 30 seconds, then the thermostat will reenter WiFi Setup mode. Reenter password for your home WiFi

Thermostat Set to Cool But Not Working, Honeywell Home

. Verify that the thermostat is switched to cool mode and has a cooling set point below the room temperature reading. 2. Check the thermostat''s display to confirm that there''s a call for cooling, usually indicated by the words "cool on" or a snowflake icon. If the "cool on" or the snowflake icon is flashing, the thermostat is in delay mode

TH5320R1002/U Honeywell Customer Portal

Product Specifications Application Gas, oil, electric, heat pump, forced warm air, hot water, steam or gravity Dimensions (in.) 3 9/16 in. High X 5 13/16 in. Wide X 1 1/2 in. Deep